#Copyright (C) 2021 Fatigue Design + Evaluation Committee of the SAE. #This data file is free software; you can redistribute it and/or modify #it under the terms of the GNU General Public License as published by #the Free Software Foundation; either version 2 of the license, or (at #your option) any later version. #This data file is distributed in the hope that it will be useful, but #WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTA- #BILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public #License for more details. #You should have received a copy of the GNU General PUblic License along #with this program; if not, write to the Free Software Foundation, Inc., #59 Temple Place - Suite 330, Boston, MA 02111-1307, USA. Try also their #web site: http://www.gnu.org/copyleft/gpl.html # # AM350 Annealed Sy=441mpa Su=1317 # Hot Rolled, Pickled and Annealed, Longitudinal 19mm diametral Spec. # Chem.: .10%C .75Mn .35Si 16.5Cr 4.25Ni 2.75Mo .10N # BHN not reported # Ref.: R.W.Smith M.H.Hirschberg S.S.Manson, "Fatigue Behavior # Ref.: of Materials under Strain Cycling in Low and intermediate # Ref.: Life Range," NASA Tech. Note D-1574, April 1963 # #FileType= strain_life #DataType= raw #TIMEcol= 0 #NAME= AM350-SS #NAME= AISI-633 #NAME= Annealed #Stress_units= mpa #Strain_units= strain #Sy= 441 # 64. ksi #Su= 1317 # 191. ksi #E= 192908 # 27978. ksi #%RA= 52.1 % #TrueFractueStess= 2337 mpa #339 ksi #TrueFractureStrain= 0.74 #BHN= 0. #NO. FAT. PTS.= 13 #StrAmpl 2Nf StsAmp So PlasStrAmpl Emod 0.0432 14 1719 0 0.03429 192908 0.0272 36 1726 0 0.01825 192908 0.017 68 1592 0 0.00875 192908 0.0107 250 1454 0 0.00316 192908 0.0084 456 1264 0 0.00185 192908 0.0067 2268 992 0 0.00156 192908 0.0055 6440 806 0 0.00132 192908 0.0047 30820 665 0 0.00125 192908 0.0035 85400 486 0 0.00098 192908 0.0038 196600 524 0 0.00108 192908 0.004 274000 548 0 0.00116 192908 0.0035 340000 462 0 0.00110 192908 0.0028 2040000 403 0 0.00071 192908 #runout # #