# Stainless 17-4PH steel H1150 Load control tests R=0.1 # NOTE!!! Use Sequiv.= sqrt(Sampl. * Smax) convert to R=-1 # Condition: H1150 Over-aged: AsRecieved + 4h@621C air cool # Chem.: 15.2%Cr 4.47Ni 3.47Cu .65Mn .38Si 0.2Nb_Ti # Chem.: 0.15Mo .03S .02C .016P # Spec.: axial 6mm diam, 18mm long gauge length. # Ref.: J-H Wu, C-K Lin, "Tensile and Fatigue Properties of # Ref.: 17-4PH Stainless Steel at High Temperatures", # Metallurgical and Matl. Trans. A, V33A June 2022 pp1715-1724 # The paper also shows data for 200C, 300C and 400C with not # much diff. except for 400C. #FileType= strain_life #DataType= raw #TIMEcol= 0 #NAME= 17-4PH_H1150 #Name= StainlessSteel #Stress_units= mpa #Strain_units= strain #Room Temp. props: #Sy= 880 mpa #Su= 966 #E= 196000 #%Elongation= 18.4 % over 25mm #BHN= 301 HRc=31.5 #Impact= 75 J Vnotched #Note!! Convert to R=-1 Seq=1.491Sa #Note!! Assume elastic for StrainEquiv. too. #StrEquivAmp 2Nf SeqivAmpl. So PlsStrAmpl Emod 0.00211 91400 617 0 0 196000 0.00206 92480 601 0 0 196000 0.00205 252660 598 0 0 196000 0.00194 461300 567 0 0 196000 0.00194 489060 567 0 0 196000 0.00194 4009200 568 0 0 196000 #runout #Raw R=0.1 load control data #Nf Sampl. #45700 414 #46240 403 #126330 401 #230650 381 #244530 381 #2004600 381 # #