# # Four Pt bending tests of AISI 9310 Carburized Steel # Shallow case depth. # Stress converted from loads using Mc/I analysis # Moment arm of load couple is 2 inch. I =0.00065104 in^4 # There were mean loads observed during testing # possibly due to transformation of Austenite #FileType= strain_life #DataType= raw #Name= AISI 9310 Steel #Name= BendingSample #Name= Iter180 #Stress_Units= ksi #Strain_Units= strain #Sy= 0 #Su= 0 #E= 24741. #monotonic_K= 0 #monotonic_n= 0. #MaterialForm= bar #FailureDef= 50% load drop #BHN= 0 #Emod below is simply StsAmpl/StrAmpl #StrAmp 2Nf StsAm So PlsStr Emod ## ksi ksi ksi 0.01005 862 223 0 0 22219 0.01001 2366 231 0 0 23106 0.00996 1200 239 0 0 24004 0.00986 2578 230 0 0 23367 0.00899 6738 199 0 0 22159 0.00823 13910 198 0 0 24029 0.00818 16944 191 0 0 23307 0.00726 17970 187 0 0 25825 0.00678 180098 172 0 0 25292 0.00672 37144 171 0 0 25482 0.00669 415120 166 0 0 24808 #fisheye 0.00608 79740 158 0 0 25924 0.00600 46260 151 0 0 25162 #fisheye 0.00590 118140 153 0 0 25955 0.00582 734280 148 0 0 25416 #fisheye 0.00566 2000000 147 0 0 26019 #runout #fisheye 0.00564 2000000 146 0 0 25915 #runout 0.00506 1388398 134 0 0 26531 0.00480 2000000 123 0 0 25564 #runout # #