#Name= SRIM #Name= FD+E_SAE_Comm. #Name= PlasticReinforced # From Kurath Report to FD&E # Table 2 # Load Control, R-0.1 Data, Unnotched, Type1 specimen # G.L.: width=15mm, GL=30mm #Stress_units= mpa #Strain_units= strain #Su= 171 mpa, ave. of 23 samples #E= 11900 mpa, ave of 18 samples # # Seq/E Smax Seq Nf # mpa mpa .00575 102 68.4 1307 .00575 102 68.4 8397 .00575 102 68.4 1978 .00575 102 68.4 3007 .00575 102 68.4 1485 .00575 102 68.4 6191 .00478 84.8 56.9 16331 .00478 84.8 56.9 6217 .00478 84.8 56.9 14646 .00478 84.8 56.9 9304 .00478 84.8 56.9 23273 .00382 67.6 45.4 537710 .00382 67.6 45.4 148520 .00382 67.6 45.4 44753 .00382 67.6 45.4 48224 .00382 67.6 45.4 59725 .00366 65. 43.6 50700 .00366 65. 43.6 43700 .00289 51.2 34.4 2308200 .00287 51.0 34.2 1000000 .00287 51.0 34.2 1185100 .00287 51.0 34.2 1956000 .00299 50. 35.6 792300 .00299 50. 35.6 734200